02 — Green Fuel Transition
Biomass Pellet Furnaces for Aluminium Melting
Fuel-cost reduction · Sustainability
Replaced LSHS-fired aluminium melting furnaces with biomass pellet burners — removed the pre-heating circuit, swapped the heavy-duty blower for a small one, eliminated black smoke, and cut fuel cost by 25%.
−25%
Fuel cost reduction
0
Black smoke emitted
Removed
LSHS pre-heating system
Renewable
Fuel source
The brief
The melting furnaces were running on LSHS (Low Sulphur Heavy Stock). LSHS needs a separate pre-heating system to flow, a heavy-duty blower to atomise and burn, and even then it threw out heavy black smoke. Fuel cost was volatile, the system was mechanically complex, and the emissions profile was indefensible. The brief: bring down cost and clean it up — without losing melt rate.
The approach
- 01Engineered a biomass pellet burner with auger-fed hopper and integrated combustion chamber sized for the existing furnace shell
- 02Removed the entire LSHS pre-heating line — no more steam coils, no more fuel viscosity management
- 03Replaced the heavy-duty atomising blower with a small-capacity blower matched to pellet combustion airflow
- 04Tied up local biomass pellet supply to lock in cost and continuity
- 05Trained furnace operators on pellet feed rate, ash removal, and combustion tuning
In motion
Biomass pellet burner running on the shop floor — clean combustion, compact blower, no pre-heating loop.
What changed
| Dimension | Before | After |
|---|---|---|
| Fuel | LSHS (fossil, heavy oil) | Biomass pellets (renewable) |
| Pre-heating | Required — separate heating circuit | Eliminated entirely |
| Blower | Heavy-duty atomising blower | Small-capacity blower |
| Emissions | Heavy black smoke | Clean burn, no visible smoke |
| Fuel cost | Baseline | −25% |
Snapshots



Got a plant problem like this one?